How To Connect Of Water Pump Automatic Pressure Switch – Automatic pressure switch is a switch component on an electric water pump machine that works automatically. The automatic pressure switch will move based on the pressure in connecting and disconnecting the flow of electricity.
The way the automatic pressure switch works is very simple. In this automatic pressure switch component, there is a spring that functions to change the position of platinum in connecting or disconnecting electricity to the water pump machine.
In its use, the automatic pressure switch is often damaged. The characteristics of damage to the automatic pressure switch are damaged is that the water pump machine does not turn on or cannot turn off automatically.
To fix the automatic pressure switch on a damaged water pump, it is generally to replace it with a new one. Well, here is a guide on how to connect automatic pressure switch for water pump.
How To Connect Automatic Pressure Switch for Water Pump
1. How To Remove And Install Automatic Pressure Switch
Before replacing the automatic pressure switch on the water pump, of course, we must first remove the components to be replaced. Here are the steps on how to remove and install an automatic pressure switch on the water pump:
- Disconnect the power cord line from the power source
- Disconnect the cable line connected to the automatic pressure switch on the water pump
- After the cable is disconnected, remove the automatic pressure switch by turning it towards the left using a wrench
- After the automatic pressure switch is released, install the sealtape in the place where the automatic pressure switch is installed
- Install a new automatic pressure switch by turning towards the right
2. How To Connect Automatic Pressure Switch Cable
To connect the automatic pressure switch cable is very easy. We only need to remember the cable connection line when the automatic pressure switch has not been removed. If you forget the position, there is no need to worry, because the cable line automatic pressure switch can be installed back and forth.
After the cable line is properly connected, do not forget to enclose it with an isolate for safety and avoid short circuits when the water pump is turned on.
3. How To Adjust Automatic Pressure Switch
If the automatic pressure switch has been installed, the next step is to do the adjusting. For automatic pressure switch setting, namely by turning the control bolts to the left or right.
To perform automatic pressure switch setting, do it by opening and closing the valve. If the valve is closed, then the water pump engine turns off, and if the valve is opened, the water pump will turn on.
If the valve is closed and the water pump does not turn off, turn the control bolts towards the right until the water pump engine turns off. If the water faucet is opened and the engine does not start, turn the control bolts towards the left until the water pumping machine can start.
Thus the discussion about how to connect automatic pressure switch for water pump. Hope it is useful.